AC Repair & Air Conditioning Service in Pelham
If your air conditioner is blowing warm air, leaking, or just not keeping up, don’t sweat it. Our team can fix all kinds of AC problems whether it’s a refrigerant issue, a bad capacitor, or a clogged drain line. We also offer routine AC service to keep your system running efficiently.
Here in Pelham, the weather doesn’t always play by the rules. It can be sunny and warm one day and chilly the next. That’s why having a dependable HVAC system isn’t optional, it’s essential. At Air Repair AL, we offer complete heating and cooling services, from quick repairs to full system replacements.
Pelham residents often see our vans near Oak Mountain State Park and the Pelham Civic Complex. Our local technicians understand the unique needs of properties throughout the area, offering quality service from the residential neighborhoods to the commercial districts.
Year-Round Comfort Starts Here
Whether your AC won’t kick on or your furnace starts acting up, you don’t have to wait days for help. We offer fast scheduling, on-time arrival, and professional service you can trust.
Need help now? Call 659-777-1111 for emergency HVAC repairs in Pelham or reach out online any time.
Furnace Repair & General HVAC Troubleshooting
When your heater stops working, especially on a cold Pelham night, we’ll be there fast. From faulty thermostats to ignition issues, we handle it all. Our heating repair service is thorough, clean, and gets your heat back on quickly.
New HVAC System Installation & Replacement
If your old unit struggles to keep up or your utility bills keep climbing, it might be time for an upgrade. We’ll help you choose the right HVAC system based on your home size and budget. We handle the entire installation or replacement process, start to finish.
Pelham Homeowner Tip: If your heating or cooling system is over 10 years old and you’re making frequent repairs, replacing it may save you more in the long run.
Heating & Cooling Maintenance Services
Regular maintenance goes a long way. Our seasonal check-ups help extend the life of your system, catch small problems early, and keep everything running safely and efficiently.
We’ll Keep Your Hot Water Flowing
There’s never a convenient time for a water heater to fail—but when it does, we’re ready. Our licensed plumbers handle everything from small fixes to full replacements, so your family isn’t stuck with cold showers.
If your water heater isn’t working right, call Air Repair AL at 659-777-1111 for emergency plumbing service in Pelham. You can also contact us online—any time, day or night.
Water Heater Repairs
Hearing odd sounds? Running out of hot water too fast? We’ll inspect your water heater, diagnose the issue, and get it working again without the guesswork.
Water Heater Installation for New Homes or Additions
Installing a water heater for a new space? We handle both standard tank and tankless water heater installations, ensuring everything’s done safely, efficiently, and up to code.
Water Heater Replacement
If your unit is rusty, leaking, or simply outdated, it may be time for a replacement. We’ll help you pick a high-efficiency model that fits your lifestyle and budget—and we’ll handle the full installation process for you.
Did You Know? A tankless water heater gives you unlimited hot water and may lower your monthly energy bills. Great for large households!
Why Pelham Homeowners Choose Air Repair AL
-
Fast emergency response
-
Clear, upfront pricing
-
Licensed HVAC & plumbing pros who know the Pelham area
-
Convenient appointment options, even after hours
-
Respectful service—because your home matters
We’re not a giant chain. We’re your local neighbors and we care about keeping Pelham families comfortable, no matter the season.
Get Expert HVAC & Water Heater Service Help in Pelham Today
Call 659-777-1111 for same-day heating, cooling, or plumbing service in Pelham, AL. Prefer to schedule online? We’re here 24/7—just send us a message!
Our Pelham Office Address
Address: 905 Belcher Dr, Pelham, AL 35124
Phone: 659-777-1111
Recent Jobs and Reviews in Pelham, AL
Our Local Reviews by City
- Abbeville, SC (1)
- Adamsville, AL (3)
- Alabaster, AL (10)
- Anderson, SC (12)
- Anniston, AL (4)
- Ashville, AL (2)
- Athens, AL (1)
- Belton, SC (1)
- Bessemer, AL (5)
- Birmingham, AL (16)
- Boiling Springs, SC (1)
- Calera, AL (1)
- Carbon Hill, AL (1)
- Center Point, AL (2)
- Chelsea, AL (2)
- Clemson, SC (1)
- Cleveland, AL (1)
- Columbiana, AL (1)
- Decatur, AL (1)
- Duncan, SC (3)
- Easley, SC (8)
- Enoree, SC (1)
- Fair Play, SC (1)
- Fountain Inn, SC (6)
- Greenville, SC (16)
- Greenwood, SC (1)
- Greer, SC (7)
- Hanceville, AL (1)
- Heflin, AL (2)
- Helena, AL (1)
- Homewood, AL (1)
- Honea Path, SC (1)
- Hoover, AL (3)
- Hueytown, AL (4)
- Inman, SC (1)
- Irondale, AL (1)
- Jasper, AL (3)
- Jemison, AL (2)
- Killen, AL (1)
- Laurens, SC (4)
- Mauldin, SC (4)
- Montevallo, AL (5)
- Montgomery, AL (3)
- Moore, SC (1)
- Morris, AL (1)
- Odenville, AL (1)
- Ohatchee, AL (1)
- Oxford, AL (3)
- Pell City, AL (2)
- Pelzer, SC (1)
- Pendleton, SC (2)
- Piedmont, SC (5)
- Pleasant Grove, AL (2)
- Powdersville, SC (1)
- Prattville, AL (2)
- Quinton, AL (2)
- Seneca, SC (3)
- Shoal Creek, AL (1)
- Simpsonville, SC (17)
- Six Mile, SC (1)
- Southside, AL (1)
- Spartanburg, SC (8)
- Taylors, SC (1)
- Travelers Rest, SC (4)
- Trussville, AL (4)
- Tuscaloosa, AL (3)
- Union, SC (2)
- Vincent, AL (2)
- Walhalla, SC (1)
- Warrior, AL (2)
- Westminster, SC (3)
- Williamston, SC (3)
- Wilsonville, AL (1)
- Woodruff, SC (2)
Job Locations and Reviews
We arrived at the call, found a very restricted drain line was able to blow it out with high pressure nitrogen. We had to cap off the tea because it was only being held by tap which made it leak in the first place. Because it wasn’t a proper seal. And the bottom of the pan secondary drain was only held by caulk. We replaced it with a T and kept it off with glue. They kept off the tee with PVC and a cap and put in a union. Also put a bull frog safety switch in the drain pan. System is now up and running //// Damage done to the garage side, but still Sheetrock. On the ceiling above water heater.
Service Report Arrived on site and performed a diagnostic evaluation of the HVAC system due to a no-cooling complaint. Upon inspection, found the system was not operating because of a failed Easy Start device that was preventing the compressor from starting properly. Removed the defective Easy Start module and tested system operation. After removal, the compressor started normally and the system resumed proper cooling operation. During the inspection, also found the air filter to be extremely dirty and heavily restricted. The clogged filter was significantly reducing airflow across the evaporator coil, causing the system to operate under excessive strain and reducing overall efficiency. Replaced the dirty filter with a new one and verified proper airflow throughout the system. Performed operational checks on the equipment and found the system is currently achieving a 20°F temperature differential between return and supply air, indicating proper cooling performance. Refrigerant opera
Arrived on site and performed evaporator coil replacement. After installation, the system was thoroughly evacuated, leak-checked, and verified for proper operation. Refrigerant charge was confirmed and all system components were inspected to ensure they were functioning within manufacturer specifications. Once repairs were completed, the system was started and monitored through a full cooling cycle. Supply air temperature at the nearest vent measured approximately 54°F, while the indoor ambient temperature was 75°F at the time of departure, indicating the system is actively cooling and performing as expected. Airflow across the evaporator coil is good, refrigerant pressures are within normal operating range, and no additional issues were observed during today’s visit. The condensate drainage system was also checked for proper operation, and all electrical connections were inspected. System is currently operating efficiently, cooling properly, and maintaining normal performance. Custo
Arrived on job and performed a full system evaluation due to the unit not cooling properly. Upon inspection, found the system low on refrigerant caused by a refrigerant leak within the system. Verified compressor operation and confirmed the compressor is currently functioning properly at this time. Further inspection indicated contamination and buildup present throughout the system, affecting overall performance and reliability. Discussed findings and system condition with customer. Due to the extent of the issues found, the job and recommendations were turned over to Andy for further evaluation, repair options, and next steps with the customer. System left in current operating condition upon departure.
Scope of Work Performed:Technician arrived on site and completed a comprehensive inspection of the main level HVAC system as well as the outdoor mini-split system. All components were evaluated for proper operation, performance, and manufacturer specifications. System Information: Main Level System: Year: 2021 Refrigerant Type: R-410A Efficiency: 14 SEER Configuration: Three-piece upflow system located in basement Outdoor Unit Location: Front side of residence Mini-Split System: Year: 2021 Findings: The main HVAC system is currently operating within manufacturer specifications and performing as designed. No major mechanical or performance-related issues were identified at this time. During inspection of the condensate drainage system, it was noted that a 3/8” copper drain line had been installed and welded in place. This configuration is not ideal for proper drainage and has contributed to a restriction/clog within the line. This condition can lead to improper condensate re
Arrived on site and spoke with the customer regarding a no-cooling concern. Performed a full system inspection and diagnostic. Determined that the issue originated in the outdoor unit, where the common wire running from the capacitor to the contactor was found to be burnt and compromised. Additionally, the capacitor was tested and confirmed to be faulty. Replaced the failed capacitor and repaired the damaged wiring. Completed a thorough system check after repairs to ensure proper operation. System is now running within normal parameters and cooling as intended. No further issues were observed at this time. System was operating properly upon departure.
Arrived on job found system vent not replaced to double wall needs to be replaced with iaq and water heater needs to be replaced
Finished coil everything running properly customer no signs of any issues
Will need to return to replace coil bad evaporator coil customer wants to do repair over replacement