Top Rated AC Repair & Installation Service in Bessemer
Is your air conditioner struggling to keep up with the summer heat? It’s a frustrating experience, especially on a hot day. Bessemer residents rely on fast, dependable heating and AC repair.
Whether your home is near the historical exhibits at the Bessemer Hall of History or located closer to the excitement of Alabama Adventure & Splash Adventure, our team delivers quick, expert service. We understand the specific system demands of properties throughout the Bessemer area.
Common Issues We Experience
Whether your unit is making a strange noise, blowing warm air, or has stopped working entirely, we can quickly diagnose the issue and get your cooling system running again.
When it’s time for an upgrade, we handle professional AC installation and AC replacement call Air Repair AL at 659-777-1111 or contact us online to schedule your service.
We’ll help you select the perfect new unit, including a high-efficiency central air system or a modern heat pump, to ensure your home stays comfortable and energy-efficient for years to come.
Comprehensive HVAC Maintenance
Don’t wait for a major system failure! Regular HVAC maintenance is the best way to extend the life of your equipment and prevent costly breakdowns.
Our seasonal inspection service includes a comprehensive check of your entire system, from the air handler to the thermostat. We also perform crucial tasks like air filter replacement to improve performance and air quality.
Investing in a yearly checkup is the smartest way to protect your investment.
Breathe Easier with Our Indoor Air Quality Solutions
The air you breathe inside your home is just as important as the air outside. We offer a range of indoor air quality solutions to help you and your family breathe easier.
By reducing common allergens, dust, and pollutants, we can help create a healthier, more comfortable living environment. Our services include everything from advanced air filtration systems to air purifiers.
HVAC Service FAQs
Why does my AC run constantly but still struggle to cool my home in Bessemer?
Many homes sit in low-lying areas with higher humidity and limited airflow around the structure. Even a properly sized AC can struggle if attic heat load and duct leakage are ignored. We often find that the issue is not the equipment itself, but heat gain from poorly sealed attic access points and older duct runs pulling in hot attic air.
Are newer HVAC systems actually worth it for older Bessemer homes?
Yes but only if the installation accounts for the home’s original layout. Many older Bessemer homes were built without modern return air design. Simply swapping equipment without correcting airflow can reduce system lifespan. The value comes from pairing new equipment with duct and airflow corrections, not just higher SEER ratings.
Why do my energy bills spike so fast during heat waves?
Bessemer heat waves often include overnight humidity that prevents your home from cooling down at night. This creates a “heat carryover” effect where the system starts the day already behind. Homes without proper dehumidification or variable-speed operation feel this the most.
Water Heater Repair and Replacement: Reliable Hot Water When You Need It
A functioning water heater is something you probably take for granted—until it stops working. Whether you have a traditional hot water tank or a modern tankless unit, our team has the expertise to get your hot water back in a hurry.
Water Heater Repair
Notice a leak, rust-colored water, or strange noises coming from your unit? These are common signs of sediment buildup and other issues.
We are experts in water heater repair and can quickly fix problems with components like the pressure relief valve or heating elements to restore your hot water heating system to proper working order.
Water Heater Replacement & Installation
If your current unit is old or beyond repair, we’ll guide you through the water heater replacement process. We’ll help you choose the best option for your home, whether it’s a new gas water heater or an electric water heater.
We can also provide a clear breakdown of the water heater installation cost upfront, so there are no surprises. When a new system is installed, you’ll enjoy improved energy efficiency and peace of mind.
Ready for Exceptional Service?
Don’t let HVAC or water heater problems disrupt your comfort. Contact Air Repair AL online for a free estimate or call 659-777-1111 now and schedule your service.
We’re here to help you with everything from ac repair to water heater installation! See what your neighbors are saying about our services below!
Recent Jobs and Reviews in Bessemer, AL
Our Local Reviews by City
- Abbeville, SC (1)
- Adamsville, AL (3)
- Alabaster, AL (10)
- Anderson, SC (12)
- Anniston, AL (4)
- Ashville, AL (2)
- Athens, AL (1)
- Belton, SC (1)
- Bessemer, AL (9)
- Birmingham, AL (18)
- Boiling Springs, SC (2)
- Calera, AL (1)
- Carbon Hill, AL (1)
- Center Point, AL (3)
- Chelsea, AL (2)
- Clemson, SC (1)
- Cleveland, AL (1)
- Clinton, SC (1)
- Columbiana, AL (1)
- Danville, AL (1)
- Decatur, AL (1)
- Duncan, SC (3)
- Easley, SC (8)
- Enoree, SC (1)
- Fair Play, SC (1)
- Fountain Inn, SC (6)
- Greenville, SC (17)
- Greenwood, SC (1)
- Greer, SC (8)
- Hanceville, AL (1)
- Heflin, AL (2)
- Helena, AL (1)
- Homewood, AL (1)
- Honea Path, SC (1)
- Hoover, AL (3)
- Hueytown, AL (4)
- Inman, SC (1)
- Irondale, AL (1)
- Jasper, AL (3)
- Jemison, AL (2)
- Killen, AL (1)
- Laurens, SC (4)
- Mauldin, SC (4)
- Montevallo, AL (5)
- Montgomery, AL (5)
- Moore, SC (1)
- Morris, AL (1)
- Odenville, AL (1)
- Ohatchee, AL (1)
- Oxford, AL (4)
- Pell City, AL (3)
- Pelzer, SC (1)
- Pendleton, SC (2)
- Pickens, SC (1)
- Piedmont, SC (5)
- Pleasant Grove, AL (2)
- Powdersville, SC (1)
- Prattville, AL (2)
- Quinton, AL (2)
- Seneca, SC (4)
- Shoal Creek, AL (1)
- Simpsonville, SC (17)
- Six Mile, SC (1)
- Southside, AL (1)
- Spartanburg, SC (8)
- Taylors, SC (2)
- Travelers Rest, SC (4)
- Trussville, AL (4)
- Tuscaloosa, AL (4)
- Union, SC (2)
- Vance, AL (1)
- Vincent, AL (2)
- Walhalla, SC (1)
- Warrior, AL (2)
- Westminster, SC (3)
- Williamston, SC (3)
- Wilsonville, AL (3)
- Woodruff, SC (2)
Job Locations and Reviews
Arrived on job found system is leaking. Water system is not level causing water to run over into ductwork. Bottom of ductwork is completely ruined. Need to replace parts of supply. Plenum also need to reseal re-level furnace properly to ensure proper operation.
Clogged drain got ac going for the time being rescheduled tune up
Rescheduled for first thing in the morning 8 19 2026
Service was good!!
System run fine at this time customer said she would let us know if anything goes wrong wrong or freeze up
Arrived on job found ductwork needs to be fixed and system needs a good cleaning and maintenance to fix issue
Did not show up to do the work
HVAC Diagnostic / Service Report Arrived on site and performed a thorough evaluation of the HVAC system. During diagnosis, it was determined that the system has additional mechanical issues beyond the previously identified compressor failure. At this time, replacing the compressor alone would not fully correct the system’s condition or provide a reliable long-term repair. Based on the overall condition of the equipment and the additional issues identified during inspection, further repairs will be necessary. The customer was informed that a compressor replacement by itself may result in continued system problems and additional repair costs. At this time, the recommended course of action is to contact American Home Shield (AHS) to discuss authorization and available options for replacing the complete outdoor condensing unit along with the indoor evaporator coil. Replacing these components together would provide a more complete repair and help ensure the system is properly matched, re
Kind of pricey
Need to re submit findings to ahs
I appreciate them getting a unit installed quickly, but the technician has been out 3 times after that, and possibly another time in the morning. It is not reaching its temperature that it's set on. I had an appointment yesterday and no one showed up.Nor did they call. They just left a house saying that it wasn't installed properly in the attic, and he had to tape it up. It was leaking air, it's set for 70, and it's reading 74, as you can tell. I'm very frustrated and upset after spending seventeen thousand dollars.
Arrived on job not keeping up due to supply not fully connected System back up and running properly
Arrived on site and performed a complete inspection and operational evaluation of the HVAC system. During testing, it was determined that the system was not delivering proper airflow throughout the home and was only producing a 12°F temperature split, indicating inadequate cooling performance. A thorough inspection of the duct system revealed a large opening in the upstairs ductwork, allowing a significant amount of conditioned air to escape before reaching the occupied living space. Based on the inspection, this issue appears to have been caused by a previous contractor who failed to properly seal and insulate the duct penetration during a prior repair or installation. The unsealed opening is resulting in substantial air loss, reduced system efficiency, and insufficient airflow to the affected areas of the home. At this time, the HVAC equipment is operational; however, it is not cooling the home properly due to the significant airflow loss caused by the damaged and improperly sealed
HVAC Service & Maintenance Report Arrived on site to perform scheduled preventive maintenance and a comprehensive inspection on all seven HVAC systems at the property. The customer recently had two of these systems replaced by our company, so special attention was given to verifying the proper operation and performance of the newly installed equipment in addition to the remaining systems. A complete maintenance inspection was performed on each system, including checking refrigerant performance, electrical components, capacitors, contactors, motors, blower assemblies, safety controls, thermostat operation, condensate drainage, air filters, and overall system operation. All systems were tested through their operating cycles to verify proper performance and ensure they were cooling and functioning as designed. Replaced all customer-provided air filters in each of the seven systems to help maintain proper airflow and system efficiency. After replacing the filters, each system was retest
Service Report Arrived on site and found the system was not operating due to the compressor not running. Performed a full diagnostic of the electrical components, including wiring and capacitor testing. Found the compressor capacitor was out of manufacturer specifications and not operating within the proper range. Replaced the faulty capacitor and restarted the system. Verified proper compressor operation and monitored system performance. Checked refrigerant pressures and confirmed they are within normal operating parameters. The system is now operating properly with no abnormal noises, electrical concerns, or performance issues observed. Completed final operational checks and confirmed the unit is functioning as designed. No further issues were found at the time of service. System was left running normally upon departure.
He was very professional and nice and got the job done pretty fast.
Arrived on site and met with the homeowner to address concerns regarding the air conditioning system not operating properly. Performed a complete diagnostic evaluation of the outdoor condensing unit and found the system was not functioning correctly due to a failed outdoor condenser fan motor. Verified that proper voltage is being supplied to the fan motor; however, the motor is non-operational and does not respond when energized. Further inspection revealed that the condenser fan motor is not moving air across the condenser coil as designed, causing the system to experience abnormal operating conditions. Due to the lack of condenser airflow, the outdoor unit is prone to freezing and overheating, which can negatively impact overall system performance and potentially cause additional component damage if operation continues. At this time, the outdoor fan motor has been diagnosed as failed and requires replacement to restore proper system operation. Discussed findings and recommended re
Arrived on site and performed compressor replacement due to a failed compressor. Removed the existing compressor and installed a new scroll compressor. Replaced all necessary components associated with the repair, brazed connections, and verified system integrity. Pulled the system into a deep vacuum to remove any moisture and non-condensable gases before charging the system to manufacturer specifications. After startup, thoroughly tested system operation and monitored refrigerant pressures, temperatures, and overall performance. Verified that refrigerant pressures were operating within the proper range and that the compressor was running smoothly and efficiently. Checked system airflow and temperature differential and obtained a 17.5°F temperature split between the supply and return air, indicating proper cooling performance. Allowed the system to run through a complete operating cycle and confirmed that all components were functioning correctly with no abnormal noises, vibrations,
Arrived on site and performed a full diagnostic evaluation of the system. Upon inspection, found the outdoor condenser fan motor had seized and was no longer operating properly. The failed fan motor caused the condenser to overheat, which resulted in compressor failure. At this time, both the condenser fan motor and compressor have been confirmed faulty and are preventing proper system operation. Recommend replacement of the condenser fan motor and compressor to restore normal system performance and ensure reliable operation.
Did a thorough tune up on my A/C unit.
Arrived on site and performed a comprehensive inspection of the entire HVAC system. Thoroughly evaluated all major components, including motors, coils, and capacitors, ensuring each was operating within manufacturer specifications. Verified proper system functionality, airflow, and overall performance. At this time, all components are operating as designed with no immediate issues or concerns observed. System is running efficiently and reliably upon departure.
There was whole/gap left from the install and I showed Corey when he came and he said he would repair it when he came to install the part and he installed the part but said someone would have to come back Monday to fix the gap. Like I explained to him I have problems with squirrels and stray animals. Other than that everything else seems to be find
Fix system running properly upon departure
Cory. Was very nice and not in a hurry took the time to listen to what I was saying.
Arrived on job knocked on door multiple times called Customer twice. No answer. Waited around for about 15 to 30 minutes. No answer may have to reschedule appointment.
Arrived on job found that customer situation is a very bad found out that the unit was installed with a spider system not getting any airflow in the basement went through expanded Customer. I would definitely recommend adding a mini split for the basement. Customer agrees have Customer penciled in for tomorrow to get system put in for basement
Installed Compressor
Arived on job found system not running due to bad board in furnace and chambers don’t look good told customer everything going on she understands and wanted to proceed with getting pre approved Customer got denied on credit. Customer also said that she is going to call her sister. She tried to call her sister when I was there sister didn’t answer. She said she’s gonna talk to her sister and see if she’ll do it for her. We’ll give us a call tomorrow and sister agrees
P-tac unit needs to be replaced old r22 customer not the home owner Land lord is going to give me a call as soon as possible Part 5187 Replacement 7987
Customer‘s cousin owns the house cousin was currently at work works two jobs night shift and dayshift. Customer is going to give me a call about 9:30 PM when Customer and Customer‘s cousin gets home to see if they want to go with indoor air quality to search protectors and a coil light.
Arrived 9-5-25 for time-up. Checked system in cooling. Checked filter condition. Checked electrical connections and components. Checked blower condition and amperage. Flushed / vacuumed drain line. Checked condition of coils - cleaned outdoor condenser coil with TriPowr foam cleaner. Checked condition of lineset. Checked condition of ductwork. Checked amperage of compressor and condenser fan. Checked refrigerant pressures. Checked indoor humidity level. Checked temperature split. ————— Found main level system (R22) had a refrigerant leak within evaporator coil, and system substantially low on refrigerant. Found rust forming within main level heat exchangers. Found main level transformer rusted and reading improperly. Found thermostat wire to main level condense missing insulation and exposed to the elements. Found excessive amount of dust / debris + microbial growth present within both duct systems. Found upstairs system drain pan covered in rust / not replaced when system wa
Arrived 8-21-25 for promotional first responder tune-up. Checked system in cooling. Checked filter condition. Checked electrical connections and components. Checked blower condition and amperage. Flushed / vacuumed drain line. Checked condition of coils - cleaned outdoor condenser coil with water only. Checked condition of lineset. Checked condition of ductwork. Checked amperage of compressor and condenser fan. Checked refrigerant pressures. Checked indoor humidity level. Checked temperature split. ————— Found 1990 R22 3-piece 2.5ton system. Found condenser had been struck by a vehicle and is now suffering from restricted pressures, along with causing both the compressor and condenser fan motor to overamp. Found heat exchangers (chambers) rusted internally, and rattling. Found every time system was touched, it appeared that something had collapsed internally. Found single-wall being used for flue pipe. Found found evaporator coil freezing up on u-bends, and rusting. Found b
Great service, only problem I had was the tech forgot to put the disconnect back in and my air wasn’t working till I figured it out.